Digital Output

Binary Output with Line Fault Transparency for Imax = 60 mA Type 9175/10-12-12 LFT
Binary Output with Line Fault Transparency for Imax = 60 mA Type 9175/10-12-12 LFT
  • Intrinsically safe output [Ex ia] IIC
  • 1 channel
  • Galvanic isolation between input and output
  • Open-circuit and short-circuit monitoring (can be switched off)
  • Line fault transparent (LFT): line fault signalling directly via output on PLC / DCS
  • Installation possible in Zone 2
  • For use up to SIL 2 (IEC 61508)

 

Zones

0

1

2

20

21

22

Ex i interfaces

X

X

X

X

X

X

Installation in

 

X

 

X

Binary Output with Line Fault Transparency for Imax = 45 mA Type 9175/10-14-12 LFT
Binary Output with Line Fault Transparency for Imax = 45 mA Type 9175/10-14-12 LFT
  • Intrinsically safe output [Ex ia] IIC
  • 1 channel
  • Galvanic isolation between input and output
  • Open-circuit and short-circuit monitoring (can be switched off)
  • Line fault transparent (LFT): line fault signalling directly via output on PLC / DCS
  • Installation possible in Zone 2
  • For use up to SIL 2 (IEC 61508)

 

Zones

0

1

2

20

21

22

Ex i interfaces

X

X

X

X

X

X

Installation in

 

X

 

X

Binary Output with Line Fault Transparency for Imax = 35 mA Type 9175/10-16-12 LFT
Binary Output with Line Fault Transparency for Imax = 35 mA Type 9175/10-16-12 LFT
  • Intrinsically safe output [Ex ia] IIC
  • 1 channel
  • Galvanic isolation between input and output
  • Open-circuit and short-circuit monitoring (can be switched off)
  • Line fault transparent (LFT): line fault signalling directly via output on PLC / DCS
  • Installation possible in Zone 2
  • For use up to SIL 2 (IEC 61508)

 

Zones

0

1

2

20

21

22

Ex i interfaces

X

X

X

X

X

X

Installation in

 

X

 

X

Binary Output for Imax = 60 mA Type 9175/.0-12-11
Binary Output for Imax = 60 mA Type 9175/.0-12-11
  • Intrinsically safe output [Ex ia] IIC / [Ex ib] IIC
  • 1 and 2 channels
  • Galvanic isolation between input, output and power supply
  • Open-circuit and short-circuit monitoring (can be switched off)
  • Installation possible in Zone 2 and Div. 2
  • For use up to SIL 3 (IEC 61508)

 

Zones

0

1

2

20

21

22

Ex i interfaces

X

X

X

X

X

X

Installation in

 

 

X

 

 

X

Binary Output for Imax = 45 mA Type 9175/.0-14-11
Binary Output for Imax = 45 mA Type 9175/.0-14-11
  • Intrinsically safe output [Ex ia] IIC / [Ex ib] IIC
  • 1 and 2 channels
  • Galvanic isolation between input, output and power supply
  • Open-circuit and short-circuit monitoring (can be switched off)
  • Installation possible in Zone 2 and Div. 2
  • For use up to SIL 3 (IEC 61508)

 

Zones

0

1

2

20

21

22

Ex i interfaces

X

X

X

X

X

X

Installation in

 

 

X

 

 

X

Binary Output for Imax = 35 mA Type 9175/.0-16-11
Binary Output for Imax = 35 mA Type 9175/.0-16-11
  • Intrinsically safe output [Ex ia] IIC / [Ex ib] IIC
  • 1 and 2 channels
  • Galvanic isolation between input, output and power supply
  • Open-circuit and short-circuit monitoring (can be switched off)
  • Installation possible in Zone 2 and Div. 2
  • For use up to SIL 3 (IEC 61508)

 

Zones

0

1

2

20

21

22

Ex i interfaces

X

X

X

X

X

X

Installation in

 

X

 

X

Binary Output Loop Powered for Imax = 60 mA Type 9176/.0-12-00.
Binary Output Loop Powered for Imax = 60 mA Type 9176/.0-12-00.
  • For intrinsically safe operation of Ex i solenoid valves, indicators and horns
  • Power supply by control circuit, loop powered
  • Intrinsically safe output [Ex ia] IIC / [Ex ib] IIC
  • 1 and 2 channels
  • Galvanic isolation between inputs and outputs
  • Installation possible in Zone 2 and Div. 2
  • Can be used up to SIL 3 (IEC 61508)

 

Zones

0

1

2

20

21

22

Ex i interfaces

X

X

X

X

X

X

Installation in

 

 

X

X

Binary Output Loop Powered for Imax = 45 mA Type 9176/.0-14-00.
Binary Output Loop Powered for Imax = 45 mA Type 9176/.0-14-00.
  • For intrinsically safe operation of Ex i solenoid valves, indicators and horns
  • Power supply by control circuit, loop powered
  • Intrinsically safe output [Ex ia] IIC / [Ex ib] IIC
  • 1 and 2 channels
  • Galvanic isolation between inputs and outputs
  • Installation possible in Zone 2 and Div. 2
  • Can be used up to SIL 3 (IEC 61508)

 

Zones

0

1

2

20

21

22

Ex i interfaces

X

X

X

X

X

X

Installation in

 

 

X

X

Binary Output Loop Powered for Imax = 29 mA Type 9176/.0-15-00.
Binary Output Loop Powered for Imax = 29 mA Type 9176/.0-15-00.
  • For intrinsically safe operation of Ex i solenoid valves, indicators and horns
  • Power supply by control circuit, loop powered
  • Intrinsically safe output [Ex ia] IIC / [Ex ib] IIC
  • 1 and 2 channels
  • Galvanic isolation between inputs and outputs
  • Installation possible in Zone 2 and Div. 2
  • Can be used up to SIL 3 (IEC 61508)

 

Zones

0

1

2

20

21

22

Ex i interfaces

X

X

X

X

X

X

Installation in

 

 

X

X

Binary Output Loop Powered for Imax = 35 mA Type 9176/.0-16-00.
Binary Output Loop Powered for Imax = 35 mA Type 9176/.0-16-00.
  • For intrinsically safe operation of Ex i solenoid valves, indicators and horns
  • Power supply by control circuit, loop powered
  • Intrinsically safe output [Ex ia] IIC / [Ex ib] IIC
  • 1 and 2 channels
  • Galvanic isolation between inputs and outputs
  • Installation possible in Zone 2 and Div. 2
  • Can be used up to SIL 3 (IEC 61508)

 

Zones

0

1

2

20

21

22

Ex i interfaces

X

X

X

X

X

X

Installation in

 

 

X

X

Binary Output Loop Powered for Imax = 43 mA Type 9176/.0-17-00.
Binary Output Loop Powered for Imax = 43 mA Type 9176/.0-17-00.
  • For intrinsically safe operation of Ex i solenoid valves, indicators and horns
  • Power supply by control circuit, loop powered
  • Intrinsically safe output [Ex ia] IIC
  • 1 and 2 channels
  • Galvanic isolation between inputs and outputs
  • Installation possible in Zone 2 and Div. 2
  • For use up to SIL 3 (IEC 61508)

 

Zones

0

1

2

20

21

22

Ex i interfaces

X

X

X

X

X

X

Installation in

 

 

X

X